Download I-view Communication Driver



Driver Download PLCs Mitsubishi. When the communication type settings for GP4201T and GP4301TM are different from those of the connected devices and further. The NI-Industrial Communications for DNP3 (Distributed Network Protocol) driver supports Ethernet and serial communication, file transfer, and time synchronization between master and outstation. These LabVIEW functions help you program on Windows computers and deploy to PXI Controllers or CompactRIO Single-Board Controllers for field applications.

Driver

Details

Note:
Precautions for adding a new driver onto Windows Vista/7
TitleFuji Electric Co.,Ltd. MICREX-SX Series Ethernet Driver
VersionVer. 1.14.07
Applicable SoftwareGP-Pro EX Ver2.10.000 or later
Pro-Server EX Ver.1.30.000 or later
You can check your version by”Help”function→”Version Info”.
Related Devices
  • MICREX-SX Series
Related UnitsRequired versions depend on models.
Please check 'Supported Models / Version' for the required versions of GP-Pro EX.
Required driver versions for different models are listed below
ModelRequired driver version
GP3000 SeriesVer. 1.10.00 or later
LT3000 SeriesVer. 1.12.05 or later
GP4100 SeriesGP4104Ver. 1.11.04 or later
GP4114Ver. 1.14.06 or later
GP4000M SeriesVer. 1.11.04 or later
GP4000 SeriesVer. 1.11.05 or later
LT4000M SeriesVer. 1.12.05 or later
SP5000 SeriesVer. 1.13.06 or later
SP5000X SeriesVer. 1.14.06 or later
IPC Series for WinGPVer. 1.10.00 or later
General PCs for WinGPVer. 1.10.00 or later
Device/PLC Connection ManualFor general information regarding Device connection and documentation conventions please refer to 'Device/PLC Connection Manual(link is external)'
Updated Contents

[Ver. 1.14.07] (Aug, 31, 2020)

The following issues were corrected:
  • When running an error check on a project, sometimes the outer limits of address ranges could not be detected properly.

How to install (This is a self-extracting file.)

Please confirm that the supported software is installed in your computer. Prior to installing the driver, close all your personal computer applications, including any resident programs such as virus detection program, etc.
  1. Click on the above file name to download the data to desired folder.
  2. After the download to your PC is finished, double-click on the file’s icon to start the installer program.
  3. After the installer starts, follow the instructions given on each screen.
  4. After installation, execute GP-Pro EX.
  5. Click on the Device/PLC area’s [Fuji Electric Co.,Ltd.] selection and select [MICREX-SX Series Ethernet].
When using the driver, be sure to refer to the Device Connection Manual PDF.Pci communication driver download
Also, for general information regarding Device connection and documentation conventions please refer to 'Device/PLC Connection Manual'.

In case of using a project, created with a version below than V1.10.03

It is necessary to reallocate a variable to a real address when using variable data.
Instructions on how to reallocate to real address.
  1. Open the project file with driver V1.10.03 or later, installed in GP-Pro EX.
  2. Open the “Variable List” dialog from the Individual Device Settings.
  3. Delete all of the worksheet(s) (This will delete all Variable Data)
  4. Delete all Structure / Array (If there are Embedded Structures / 2D Arrays then the higher level must be deleted first.)
  5. Import / Re-enter Structures / Arrays
  6. Import / Re-enter Variables
  7. Click OK to close dialog
  8. Click OK to save new Variable Data
* Please don’t close the “Variable List” dialog while doing the procedures above. If the “Variable List” dialog is closed, the allocated variables to the parts in the screen will become “-Undefined-“.

Terms of use / Cautions

Please acknowledge the following terms of use before you use our download service.
Download of any file signifies your agreement to the terms of use.
Terms and conditions

Download file

Installer :
1.02 MB (1,069,304Byte)
Device/PLC Connection Manual :
818.51 KB (838,152Byte)

Pci Communication Driver Download

Update history:


[Ver. 1.14.07] (Aug. 31, 2020)

The following issues were corrected:Download iview communication drivers
  • When running an error check on a project, sometimes the outer limits of address ranges could not be detected properly.


[Ver. 1.13.06]

Hht driver download

The following issues were corrected:
  • Variable data cannot be imported normally when D300win V3.6.1.3 or later is used.


[Ver. 1.10.03] (Dec. 24, 2010)

Usb Communication Driver

The following issues were corrected:
  • In rare cases, a variable that have been allocated to a real address, is unmatched with the Fuji Electric Co. Ltd. Micrex-SX Series D300Win software.
  • In rare cases, the displayed address in the left side of the [Address] window is unfinished.
  • In rare cases, putting a comment or space in the IEC file will result in an error when importing.


[Ver. 1.10.02] (Nov. 12, 2009)

The following issues were corrected:
  • GP-Pro EX may be forcibly terminated when the address input dialog is opened.
  • GP-Pro EX may stop responding when import is performed and variables are overwritten.


[Ver. 1.10.01](May. 8, 2008)

The following issues were corrected:
  • When create structure in variable data, there is the case that display cannot communicate with PLC.

Cable Drivers

MD-CC3/4 and Windows x64 systems

The older versions of the MD-CC30x-001 USB to SPI and MD-CC40x-001 USB to RS-422/485 communication converter cables were developed to work with Windows 32-bit operating systems. These cables must have the the internal ID reset in order to be supported by current Windows 64-bit operating systems.

How do I know if I have an older cable?

The most recent cable will install as 'Silicon Labs C210x USB to UART Bridge (COMXX)' in the device manager of your PC under Ports (COM and LPT).

In the case of MD-CC3 and MD-CC4 cables with the incompatible ID, when the device manager attempts to find the drivers and fails to install them, the message that opens will show the IMS part number: MD-CC400-000 or MD-CC300-000 on the dialog, as shown below.

Additionally, the part number will display under other devices in your computer's device manager.

Please contact applications for information on cable updates

MD-CC404-000 & MD-CC405-000
The MD-CC404/5-000 drivers are applicable to Lexium MDrive RS-422/485 products. This device is 'plug-n-play' and the drivers should automatically install to an Internet connected PC. Should your network block automated driver installs or the PC not be connected, the drivers may be downloaded from:

MD-CC404-000 Drivers (FTDI VCP Drivers)
Note: This link will open in a new browser tab/window.

MD-CC40x-001
The MD-CC40x-001 drivers are applicable to MDrivePlus and MForce Motion Control RS-422/485 products. This device is 'plug-n-play' and the drivers should automatically install to an Internet connected PC. Should your network block automated driver installs or the PC not be connected, the drivers may be downloaded from:

MD-CC40x-000 Drivers (Silicon Labs CP210x USB to UART Bridge VCP)
Note: This link will open in a new browser tab/window.

Legacy MD-CC40x-001 drivers

Iview

Use ONLY with CC4 cables with the IMS ID on 32 bit Windows systems

Driver Package | Installation Instructions

Download Iview Communication Drivers

MD-CC30x-001
The MD-CC30x-001 drivers are applicable to MDrivePlus and MForce Step/direction and Speed Control SPI products. This device is 'plug-n-play' and the drivers should automatically install to an Internet connected PC. Should your network block automated driver installs or the PC not be connected, the drivers may be downloaded from:

MD-CC30x-001 Drivers (Silicon Labs CP210x USB to UART Bridge VCP)
Note: This link will open in a new browser tab/window.

Legacy MD-CC30x-001 drivers

Use ONLY with CC3 cables with the IMS ID on 32 bit Windows systems

Driver Package | Installation Instructions

MD-CC50x-000

These drivers apply to the MD-CC500-000 (MDrivePlus and MForce products) and MD-CC501-000 (Lexium MDrive products) USB to CANopen Communications converters

MD-CC50x-000 Drivers (PEAK Systems PCAN-USB)
Note: This link will open in a new browser tab/window.